Specifications Table for ATXM-R / ARXM-R

ATXM25R2V1B / ARXM25R5V1B ATXM25R5V1B / ARXM25R5V1B ATXM35R2V1B / ARXM35R5V1B ATXM35R5V1B / ARXM35R5V1B ATXM50R2V1B / ARXM50R2V1B
Cooling capacity Min. kW 1.30 1.30 1.40 1.40 1.70
  Nom. kW 2.50 2.50 3.40 3.40 5.00
  Max. kW 3.20 3.20 4.00 4.00 6.00
Heating capacity Min. kW 1.30 1.30 1.40 1.40 1.70
  Nom. kW 2.80 2.80 4.00 4.00 5.80
  Max. kW 4.70 4.70 5.20 5.20 7.70
Nominal efficiency EER   4.50 4.50 4.23 4.23 3.45
  COP   5.00 5.00 4.04 4.04 3.79
  Annual energy consumption kWh 278 278 402 402 725
  Energy labeling Directive Cooling   A A A A A
    Heating   A A A A A
Space cooling Capacity Pdesign kW 2.50 2.50 3.40 3.40 5.00
  Energy efficiency class   A+++ A+++ A+++ A+++ A++
  SEER   8.55 8.55 8.55 8.55 7.35
  Annual energy consumption kWh/a 102 102 139 139 238
Space heating (Average climate) Capacity Pdesign kW 2.40 2.40 2.50 2.50 4.60
  Energy efficiency class   A+++ A+++ A+++ A+++ A++
  SCOP/A   5.10 5.10 5.10 5.10 4.65
  Annual energy consumption kWh/a 659 659 686 686 1,384
Notes (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range  
  (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data  
  (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.  
  (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.